- Client
- Ernneka
- Environment
- Retail & Commercial
- Location
- Oritshe Street, Lagos
- Project period
- February 2026
The installation at a glance.
- 2
- Business premises
- 9.44 kWp
- Shop PV nameplate rating
- 5.72 kWp
- Office PV nameplate rating
Shop
- Inverter
- 12 kVA hybrid
- Battery
- 15 kWh lithium
- Solar PV
- 16 × 590 W Jinko · 9.44 kWp
Office
- Inverter
- 10 kVA hybrid
- Battery
- 15 kWh lithium
- Solar PV
- 8 × 715 W Jinko · 5.72 kWp
PV nameplate capacity is calculated from panel quantity × rated wattage. It describes the installed panel rating, rather than measured daily generation.
The requirement.
Ernneka's shop and office needed separate solar installations. The two premises were not specified with identical equipment: the shop had a larger inverter rating and a different panel array from the office.
The requirement was to bring solar generation, inverter conversion and battery storage together at both premises while preserving each installation's individual configuration. The project record supplies equipment quantities, but not load-assessment results or a measured energy baseline.
How the solution came together.
The shop installation paired a 12 kVA hybrid inverter with a 15 kWh lithium battery and sixteen 590 W Jinko panels. The panels have a combined nameplate rating of 9.44 kWp, calculated as 16 × 590 W.
The office installation used a 10 kVA hybrid inverter, a 15 kWh lithium battery and eight 715 W Jinko panels. This array has a calculated nameplate rating of 5.72 kWp. Both systems included the same recorded battery energy capacity, while their inverter ratings and panel configurations differed.
- Shop: 12 kVA hybrid inverter, 15 kWh lithium battery and 16 × 590 W Jinko panels.
- Office: 10 kVA hybrid inverter, 15 kWh lithium battery and 8 × 715 W Jinko panels.
The delivered scope.
The completed scope provided two commercial premises with solar generation, hybrid inverter equipment and lithium storage. It shows how separate business locations can use different combinations of panels and inverter capacity rather than a single standard package.
The panel ratings describe installed nameplate capacity. They are not a prediction of daily energy generation, and the records do not quantify fuel savings, electricity savings or backup duration.
System details, up close.